Always check unit before applying power (see Sections 6-1 thru 6-18).
TM-229 409 Page 47Extreme 360
6-29. Front Panel/Display Board PC3 Testing Information (Use with Section 6-30)
Ref. 217 181-B / 907 161
Y Warning this procedure re-
quires the machine to be
electrically live. Significant
DC voltage can remain on ca-
pacitors after unit is Off.
Be sure plugs are secure before ap-
plying power. See Section 6-30 for
specific values during testing.
1 Process Control Board PC3
2 Receptacle RC1
3 Receptacle RC2
4 Receptacle RC51
Test Equipment Needed:
1
2
4
3